Products for flow measurement - Coriolis mass flowmeters
Simultaneous measurement of mass, density, temperature and viscosity
General
The advantages of Coriolis mass-flow measurement are self-evident. It comes as no surprise, therefore, to find that this principle is used in a huge range of industry sectors, including pharmaceuticals, chemicals and petrochemicals, oil and gas, food, and also in custody transfer applications in general.
Virtually all fluids can be measured: cleaning agents and solvents, fuels, vegetable oils, animal fats, latex, silicon oils, alcohol, fruit solutions, toothpaste, vinegar, ketchup, mayonnaise, gases, liquefied gases, etc.
One for all - multivariable metering. The ability to measure several process variables all at the same time opens up completely new application fields. Mass flow, density and temperature (the primary measured variables) can be used to derive other variables such as volume flow, solid contents, concentrations, and complex density functions.
Transmitters
Unified operating concept, flexible outputs, software packages, Fieldbus interface, Ex-approvals and much more - all a matter of course for Promass transmitters.
Promass 40
- Cost-effective transmitter for low-end applications
- No local operating interface
Promass 80
- Transmitter for all standard applications
- Two-line, backlit display
- Pushbutton controls
Promass 83
- With extended functionality suitable for special applications
- Four-line, backlit display
- "Touch Control" operation from outside
- Viscosity measurement
- Measures pulsating flow
- F-Chip (software upgrade options): filling and dosing, density/concentration functions (standard density,
°Brix, °Baumé, °API, °Balling,
°Plato), advanced diagnostics - HistoROM / T-DAT: Data memory for device parameters
Promass 84
- For custody transfer
- Approvals for PTB and NMi, more approvals in preparation
- With extended functionality suitable for special applications
- Four-line, backlit display
- "Touch Control" operation from outside
- Measures pulsating flow
- HistoROM / T-DAT: Data memory for device parameters
Promass 200
-
True 2-wire transmitter (4-20 mA, loop-powered)
-
For processes in the chemical industry or for utilities
-
Reduced installation costs
-
Task-oriented operating concept for the quick and safe commissioning (operator, maintenance and expert menus, tool tips, etc.)
-
Display module with backup and transfer function for configuration data (e.g. to other measuring points)
-
HistoROM: Automatic data backup for fast exchange of electronics without recalibration
Sensors
The Promass sensors covers a very wide range of requirements. The choice of materials, process connections, hygienic versions, accessories etc. is correspondingly broad.
Accuracy: typically ±0.1% of reading (mass flow, liquids).
Promass A
- For very low flow rates and high pressure, DN 1...4 (1/24...1/8"), up to PN 400 (5800 psi)
- Tube materials: Stainless steel, Alloy C-22
- Also for custody transfer
Promass E
- Cost-effective sensor for low-end applications,
DN 8...80 (3/8...3") - Tube material: Stainless steel
Promass F
- For universal use, DN 8...250 (3/8...10")
- Tube material: Stainless steel, Alloy C-22
- High-temperature version up to 350 °C (660 °F)
- Also for custody transfer
Promass H
- Single-tube system especially for chemically agressive fluids, DN 8...50 (3/8...2")
- Tube material: Zirconium, Tantal
Promass I
- Straight, easily cleanable single-tube system for hygienic applications, DN 8...80 (3/8...3")
- Tube material: Titanium
- Viscosity measurement (optional)
Promass O
- The universal and multivariable flowmeter for liquids and gases
- DN 80 to 150 (3" to 6")
- Fluid temp. up to
+200 °C (+392 °F) - Process pressures up to
258 bar (3750 psi) - Mass flow measurement up to 800 t/h (29 400 lb/min)
- Ex-Approvals: ATEX, FM, CSA, TIIS, IECEx, NEPSI
Promass P
- Single-tube hygienic sensor for life sciences industries, DN 8...50 (3/8...2")
- Complying with industry standards, e.g. ASME, BPE, ISPE, FDA, EHEDG and 3A
- Tube material: Stainless steel
Promass S
- Single-tube hygienic sensor for the food industry, DN 8...50 (3/8...2")
- Standard approvals: 3A, EHEDG, FDA and SIL2
- Tube material: Stainless steel
Promass X
- Highly precise 4-tube technology for flow measurement of largest capacities in the oil and gas industry
- Flanges: DN 300, 350, 400 (12", 14", 16")
- Fluid temp. up to
+180 °C (+356 °F) - Process pressures up to
100 bar (1440 psi) - Mass flow measurement up to 4100 t/h (4520 tn. sh./h)
- Ex-Approvals: ATEX, FM, CSA, TIIS, IECEx, NEPSI
Dosimass
- Mass flow measuring system for filling applications
- DN 08 to 25 (3/8" to 1")
- 3A approval
- Extremely compact
- High repeatability
- For very short filling times
More information about 8BE
CNGmass
- Specially designed flowmeter for fueling vehicles with CNG (compressed natural gas)
- Fluid temp. up to +125 °C (+257 °F)
- Process pressures up to 350 bar (5080 psi)
- Mass flow measurement up to 150 kg/min (330 lb/min)
- Ex-Approvals: ATEX, FM, CSA, NEPSI
More information about 8FF
CNGmass DCI
-
Specially designed flowmeter for fueling vehicles with CNG (compressed natural gas)
-
Fluid temp. up to +150 °C (+302 °F)
-
Process pressures up to 350 bar (5080 psi)
-
Mass flow measurement up to 150 kg/min (330 lb/min)
-
Ex-Approvals: ATEX, NEC/CEC, NEPSI
More information about 8DF
LPGmass
- Specially designed flowmeter for fueling vehicles with LPG (liquified petroleum gas) and filling in hazardous areas
- Fluid temp. up to +125 °C (+257 °F)
- Process pressures up to 100 bar (1450 psi)
- Mass flow measurement up to 750 kg/min (1654 lb/min.)
- Big range of process connections
- Ex-Approvals: ATEX, FM, CSA
More information about 8FE
Cubemass
-
The flowmeter for precise measurement of minimal flows
- Compact size, low weight, small footprint, highly accurate
- Fluid temp. up to +200 °C (+392 °F)
- Process pressures up to 400 bar (5800 psi)
- Mass flow measurement up to 1000 kg/h (36.75 lb/min.)
- Ex-Approvals: ATEX, NEC/CEC, NEPSI
More information about 8CM
Cubemass DCI
-
The flowmeter for precise measurement of minimal flows
-
Four-line liquid crystal display
- Compact size, low weight, small footprint, highly accurate
- Fluid temp. up to +200 °C (+392 °F)
- Process pressures up to 400 bar (5800 psi)
- Mass flow measurement up to 1000 kg/h (36.75 lb/min.)
- Ex-Approvals: ATEX, NEC/CEC, NEPSI
More information about 8CN