General

Is reaction time a critical parameter for your application? You will certainly find an adequate answer amongst this Line of products, which have no additional protecting tube, so that the probe sheath is directly in contact with the precess medium.

This allows the sensors to accurately detect very fast temperature changes.

Omnigrad

TST310

TST310

  • RTD thermometer, can be screwed in or inserted
  • Fixed connected cable and anti-kink spring
  • Fast response time
  • Measurement range:
    -50 to +400 °C (-58 to +752 °F), mineral-insulated sheated cable
    -50 to +250 °C (-58 to +482 °F), insulated sensor wires

More information about TST310

TST602

TST602

  • Surface RTD thermometer with insulated cable
  • Measurement range: 
    -20...+180°C (-4...+356°F)

More information about TST602

TSC310

TSC310

  • TC thermometer, can be screwed in or inserted
  • Fixed connection cable and anti-kink spring
  • Fast response time
  • Measuring range:
    Type J: -210 to +760 °C
    (-346 to +1400 °F)
    Type K: -270 to +1100 °C
    (-454 to 2012 °F)

More information about TSC310

Easytemp

TMR31

TMR31

  • To screw in
  • Temperature range:
    -50…+200°C (-58...+392°F)
  • Cable plug: M12
  • Ingress protection: IP66/67

More information about TMR31

TMR35

TMR35

  • For hygienic applications (3A, EHEDG)
  • Temperature range:
    -50…+200°C (-58...+392°F)
  • Cable plug: M12
  • Ingress protection: IP66/67

More information about TMR35

U.S. products

TH12

TH12

  • General purpose RTD assembly with cable
  • Measurement range:
    -58...392°F  (-50...200°C)
    -328...1112°F (-200...600°C)

More information about TH12

TH52

TH52

  • General purpose MgO insulated thermocouple assembly with cable.
  • Measurement range:
    -454...2500°F (-270...1000°C)

More information about TH52

TH56

TH56

  • General purpose MgO insulated thermocouple assembly with plug.
  • Measurement range:
    -454...2500°F (-270...1000°C)

More information about TH56

TSM470F

TSM470F

  • Compact RTD, meets 3-A standard surface finish requirements.
  • Built-in transmitter
  • Loop powered, 4-20mA output
  • PC programmable
  • Measurement range:
    -60...320°F  (-51...160°C)

More information about TSM470F

TSM470G

TSM470G

  • Compact RTD fully sealed assembly with built-in transmitter.
  • Loop powered, 4-20mA output
  • PC programmable
  • Measurement range:
    -60...320°F  (-51...160°C)

More information about TSM470G

TSM470P

TSM470P

  • Compact RTD, meets ASME BPE-2002, Bio processing standard surface finish requirements.
  • Built-in transmitter
  • Loop powered, 4-20mA output
  • PC programmable
  • Measurement range:
    -60...320°F  (-51...160°C)

More information about TSM470P

South Africa products

TLSC2

TLSC2

  • Thermocouple sensor with fixed insert, adjustable compression fitting
  • Assembly with flexible tails and quick disconnect plugs and jacks
  • Customized immersion length
  • Measurement range:
    -270...1100°C (-454...2012°F )

More information about TLSC2

TLSR2

TLSR2

  • RTD measuring sensor with fixed insert, adjustable compression fitting
  • Assembly with flexible tails
  • Customized immersion length
  • Measurement range:
     -200...600°C (-328...1112°F)

More information about TLSR2